Gel Filtration Chromatography: Principle, Sephadex Gels and Protein Purification

Take a bottle of cell extract — the broken-open contents of cells, holding hundreds of different proteins mixed together. How do you pull one protein away from the rest, gently, without heat, without chemicals that bind, and without breaking anything? Gel filtration is the answer: one column of tiny porous beads, a pump, and a buffer (a salt solution at a fixed pH). The big molecules rush straight through. The small ones take the long way round. Half an hour later each size has come out in its own tube, still in its natural shape and still active. That is why almost every protein laboratory in the world keeps a gel filtration column next to the bench — it is the gentlest way to clean up, desalt, and measure a protein.
Think of it like a race through a city of sponge buildings. The big runners cannot fit through any door, so they run straight down the main streets and finish first. The small runners slip into the buildings, wander through the corridors, and come out much later. The middle-sized runners fit through some doors and not others, so they finish in between — biggest first, smallest last. The doors are the pores in the gel beads, and the race is the whole lesson: elution order, Kav, calibration curves, desalting, and why gel filtration is both gentle and low in resolution.
Did you know? Gel filtration began in 1955, when Lathe and Ruthven separated proteins on swollen starch gels. Four years later, in 1959, Jerker Porath and Per Flodin coined the term "gel filtration" and introduced cross-linked dextran — Sephadex — the gel that made the technique routine. Polyacrylamide gels followed in 1962 (Hjertén and Mosbach), and in 1964 John Moore carried the same idea into polymer science as gel permeation chromatography (GPC). The beads changed; the idea — sort molecules by size — never did.
Exam coverage: Chromatography is tested in GCSE Chemistry (AQA 8462 §5.8 — paper chromatography and Rf; gel filtration itself is not a GCSE requirement, but it is the protein example that A-level and university courses build on), AQA A-level Chemistry 7405 §3.3.16, OCR A Chemistry H432 §6.3.1, Cambridge International 9701 §37.1, AP Chemistry Unit 3, IB Chemistry and Biology, MDCAT Unit 3 (Biological Molecules) and NEET (NCERT Class 11, Chapter 12 — the chromatography family; Class 12, Biomolecules — protein purification). Gel filtration's real home is the university biochemistry practical, where it is the standard protein purification step — this lesson marks clearly which parts are syllabus core and which are extensions.
Contents
- What is gel filtration chromatography?
- Gel filtration at a glance
- How does gel filtration work? The principle
- The three volumes: V0, Vt and Ve
- Kav: the number that places every molecule
- Characteristics of gel filtration chromatography
- The gels: Sephadex, Sepharose, Superdex and Sephacryl
- Group separation or fractionation: two different jobs
- The instrument: pump, column, detector, fraction collector
- Desalting and buffer exchange, step by step
- Procedure: running a gel filtration column step by step
- Reading a chromatogram: the calibration curve
- Gel filtration in protein purification
- Uses of gel filtration chromatography
- Gel filtration vs other chromatography
- Troubleshooting and safety
- 10 exam traps
- Key points
- Frequently asked questions
- Practice MCQs
- Quiz: test yourself
- Continue learning
- Sources
What is gel filtration chromatography?
Gel filtration chromatography is a way of separating the molecules in a water-based mixture by their size. It is one of several methods in the chromatography family, each separating by a different property. The column is a glass or steel tube packed with tiny porous beads made of a soft gel — cross-linked dextran (Sephadex), agarose (Sepharose), or polyacrylamide (Bio-Gel). The beads are full of pores (tiny tunnels) of a chosen size range, and they sit in a buffer that flows slowly down the column. That buffer is the mobile phase (the part that moves). The beads are the stationary phase (the part that stays still) — but unlike other chromatography, the beads do not grab or bind anything. They only offer pores to hide in.
A small volume of the mixture is layered gently on top of the bed, and buffer is pumped through. Each molecule now faces the same choice at every bead: fit into a pore, or walk around the bead. A molecule larger than the largest pore cannot enter any bead, so it walks only between the beads — the shortest route — and comes out first. A molecule smaller than the smallest pore can enter every bead, so it wanders through pore after pore — the longest route — and comes out last. A middle-sized molecule enters some pores and not others, so it comes out in between. The result is a row of peaks on a chromatogram, biggest first, smallest last — the opposite order from paper chromatography, where the smallest, most soluble compounds travel furthest.
Three names describe one technique, and students mix them up more than any other fact in this lesson. Size exclusion chromatography (SEC) is the general name. When the mobile phase is water-based (a buffer), the technique is called gel filtration chromatography — the name used for proteins, enzymes, nucleic acids and sugars. When the mobile phase is an organic solvent, it is called gel permeation chromatography (GPC) — the name used for synthetic polymers such as polystyrene. A fourth name, molecular sieve chromatography, describes the same sieving idea. If a question says "gel filtration", it means SEC in water; if it says "GPC", it means SEC in organic solvent. The companion lesson on size exclusion chromatography covers the same technique from the general side, and the two posts are companions, not rivals.
Gel filtration is used wherever a molecule must be separated without being changed. Proteins come out still folded and still active, because nothing binds them and no harsh solvent is used. That gentleness is the reason gel filtration is the final "polishing" step in protein purification, the standard way to desalt a sample, and the routine way to estimate a protein's molecular weight — and also the reason its resolution is low, as this lesson explains honestly in the traps section.
Gel filtration at a glance
| Feature | In gel filtration |
|---|---|
| Separates by | Size — hydrodynamic volume (Stokes radius), not mass alone |
| Elution order | Largest first (at V0), smallest last (at Vt) |
| Stationary phase | Porous gel beads (Sephadex, Sepharose, Bio-Gel); nothing binds |
| Mobile phase | Water-based buffer (gel filtration) or organic solvent (GPC) |
| Key number | Kav = (Ve − V0) ÷ (Vt − V0), between 0 and 1 |
| Two jobs | Group separation (desalting, short column) and fractionation (many sizes, long column) |
| Strength | Gentle — molecules come out unchanged and active |
| Weakness | Low resolution — similar sizes cannot be separated |
How does gel filtration work? The principle
The principle is steric exclusion (molecular sieving): separation by whether a molecule can physically fit into a pore. Each bead is a microscopic sponge. Its pores come in a range of sizes, set by how tightly the polymer is cross-linked (the more cross-links, the smaller the pores). A molecule in the flowing buffer meets bead after bead, and at each one its size decides its route:
- Too big for every pore — the molecule is excluded. It can only travel in the liquid between the beads, so it takes the shortest path and elutes first, at the void volume V0.
- Small enough for every pore — the molecule is fully included. It diffuses into the pores of bead after bead, so it takes the longest path and elutes last, at the total volume Vt.
- In between — the molecule enters some pores and is excluded from others. It elutes between V0 and Vt, and its exact position depends on how much pore volume it can enter — which is exactly what Kav measures.
Two points make the principle click. First, the separation is purely physical: no charge, no binding, no chemical reaction. A protein and a sugar of the same size elute at the same volume even though their chemistry is entirely different. Second, what matters is hydrodynamic volume — the effective size of the molecule in solution, including the water shell it drags along — not the molecular weight printed on the bottle. A long, thin protein sweeps out a bigger volume than a compact, round protein of the same mass, so the thin one elutes first. That is why a calibration curve gives an apparent molecular weight, and why shape is one of the exam traps in this lesson.

The photograph above shows the last moment of a gel filtration run: a drop of eluate (the liquid coming out of the column) falling from the column outlet into a small collection tube. Each tube catches one fraction — one slice of the run — and the tubes are tested afterwards to find which one holds the target protein. What the photograph does not show is the separation itself: the beads are white and the buffer is colourless, so a protein run is invisible to the eye — the peaks exist only on the detector's screen.
Watch it happen: a gel filtration run, step by step.
Pack
Load
Big out
Small out
Desalt
The three volumes: V0, Vt and Ve
Every gel filtration run is described by three volumes. Learn them as a picture, not as letters: the column is a tube of beads, and buffer fills both the gaps between the beads and the pores inside them.
| Symbol | Name | What it is |
|---|---|---|
| V0 | Void volume | The volume of buffer in the spaces between the beads. It is the elution volume of a molecule too large to enter any pore. Measured with Blue Dextran (about 2,000 kDa, deep blue, fully excluded). |
| Vt | Total volume | The geometric volume of the packed bed: cross-sectional area × bed height (Vt = πr²h). It is the elution volume of a molecule small enough to enter every pore, such as a salt ion or acetone. |
| Ve | Elution volume | The volume of buffer that must pass through before a given molecule's peak comes out. Read straight from the chromatogram for each peak. |
Two useful checks follow from these definitions. First, the pore volume inside the beads (Vi) is roughly Vt − V0, and as a rule of thumb V0 is about one-third of the bed volume while the pore volume is about two-thirds — so if a column holds 110 mL of bed, expect V0 near 37 mL and Vt of 110 mL. Second, every molecule elutes between V0 and Vt: nothing can come out before V0 (there is no shorter route) and nothing after Vt (the column has no route beyond the pore volume). If a peak appears outside that window, something is wrong — usually adsorption to the gel, which is a fault to fix, not a result to report.
Kav: the number that places every molecule
Elution volumes depend on the column: the same protein has a different Ve on a fat column and a thin one. Kav removes the column from the answer. It is the fraction of the pore volume a molecule can enter:
Kav = (Ve − V0) ÷ (Vt − V0)
Kav always lies between 0 and 1. Kav = 0 means the molecule is fully excluded (it elutes at V0). Kav = 1 means it enters every pore (it elutes at Vt). Everything worth separating falls in between — and the straightest part of the calibration curve, where molecular-weight estimation works best, is roughly Kav 0.1 to 0.7. An older coefficient, Kd = (Ve − V0) ÷ Vi, says the same thing with the true pore volume Vi, but Vi is hard to measure exactly, so Kav — which uses only the two volumes anyone can measure — is the number every laboratory actually reports.
Worked example 1 — Kav from a run. A column has total volume Vt = 100 mL and void volume V0 = 35 mL (measured with Blue Dextran). A protein elutes at Ve = 74 mL. Its Kav is (74 − 35) ÷ (100 − 35) = 39 ÷ 65 = 0.60. The protein can enter 60% of the pore volume. A second protein on the same column elutes at Ve = 48 mL: Kav = (48 − 35) ÷ 65 = 13 ÷ 65 = 0.20 — a much larger molecule, able to enter only one-fifth of the pores.
Worked example 2 — Kav from the other end. On a column with V0 = 30 mL and Vt = 110 mL, a compound elutes at Ve = 70 mL. Kav = (70 − 30) ÷ (110 − 30) = 40 ÷ 80 = 0.50. Notice the pattern: the closer Ve sits to Vt, the closer Kav sits to 1, and the smaller the molecule. Exam questions love this direction — give Ve, V0 and Vt, ask for Kav — and the arithmetic is always one subtraction on top, one on the bottom, then a division.
Characteristics of gel filtration chromatography
- Separation by size alone. Charge, polarity and chemistry do not matter in ideal gel filtration — only hydrodynamic volume. A protein and a sugar of the same size elute together.
- Largest first, smallest last. The elution order is the opposite of most other chromatography, and it never changes.
- No binding. The gel is chemically inert. Molecules are not adsorbed, so they come out unchanged, folded and active. Any binding that does happen is a fault (usually fixed by adding salt to the buffer).
- Gentle conditions. Runs happen in ordinary buffers at room temperature, with no heat and no harsh solvents, so fragile proteins and enzymes survive.
- Low resolution. Peaks are broad and the peak capacity is small. Molecules of similar size cannot be separated — roughly a two-fold difference in molecular weight is needed for a clean split.
- Short, predictable runs. Everything elutes between V0 and Vt, so a run ends after about one bed volume of buffer. Nothing is retained indefinitely.
- Sample stays dilute. The sample spreads out as it travels, so the collected fractions are more dilute than the loaded sample — a real cost when the product must be concentrated afterwards.
- Simple to run. One buffer, one column, one detector. No gradients, no pH steps, no elution tricks — which is why gel filtration is often the first chromatography a student meets in a protein laboratory.
The gels: Sephadex, Sepharose, Superdex and Sephacryl
The gel is the heart of gel filtration, and choosing it means choosing a pore size. Each gel is sold in "G-numbers" or grades, and each grade is defined by two numbers: the fractionation range (the molecular weights it can spread out, for globular proteins) and the exclusion limit (the molecular weight above which everything elutes together at V0). A protein outside the range cannot be resolved on that gel — too big and it all comes out at V0; too small and it all comes out at Vt.
| Gel | Globular proteins it separates | Best use |
|---|---|---|
| Sephadex G-25 | 1,000–5,000 Da | Desalting and buffer exchange |
| Sephadex G-50 | 1,500–30,000 Da | Small proteins and peptides |
| Sephadex G-75 | 3,000–80,000 Da | Medium proteins |
| Sephadex G-100 | 4,000–150,000 Da | Most ordinary proteins |
| Sephadex G-150 | 5,000–300,000 Da | Large proteins |
| Sephadex G-200 | 5,000–600,000 Da | Very large proteins |
| Sepharose 6B | 10,000–4,000,000 Da | Huge molecules, viruses, plasmids |
| Superdex 75 | 3,000–70,000 Da | Sharper peaks at higher flow, medium proteins |
| Superdex 200 | 10,000–600,000 Da | Sharper peaks at higher flow, large proteins |
| Sephacryl S-200 HR | 5,000–250,000 Da | Rigid beads for fast runs |
| Bio-Gel P-30 | 2,500–40,000 Da | Polyacrylamide alternative to G-50 |
Four families cover almost all work. Sephadex is cross-linked dextran (a polymer of glucose) — soft, cheap, and the classic teaching gel; its G-number rises as the pores get bigger, and G-25 is the desalting workhorse. Sepharose is agarose (from seaweed) — bigger pores for bigger molecules. Bio-Gel P is cross-linked polyacrylamide — a synthetic alternative with sharp fractionation ranges. The modern laboratory mostly runs Superdex and Superose: composites of agarose and dextran whose small, rigid, uniform beads survive higher flow rates and give sharper peaks than classic Sephadex, while Sephacryl (allyl dextran cross-linked with bisacrylamide) is rigid for the same reason. Whichever gel is chosen, it must be swollen in buffer before packing (dry Sephadex swells several-fold in water), and it must never be allowed to dry out or freeze once packed.

The photograph above shows two empty glass columns for gravity liquid chromatography, lying flat with a centimetre scale at the bottom left. The stopcock with the blue tap at the right end controls the flow out of the column. These columns are empty: the gel is poured in as a slurry before a run, and the bed — the packed gel — is what does the separating. What the photograph does not show is the bed itself, because the columns have not been packed yet.
Group separation or fractionation: two different jobs
Gel filtration does two different jobs, and the column, the sample size and the goal are different for each. Mixing them up is the most common practical mistake in this lesson.
| Job | Column | Sample volume | Goal |
|---|---|---|---|
| Group separation (desalting, buffer exchange) | Short — even a spin column | Up to about 30% of the bed volume | Two groups: big out at V0, small out at Vt |
| Fractionation (separating several proteins) | Long — resolution grows with bed height | At or below about 2% of the bed volume (5% at most) | Many sizes spread out into many fractions |
Group separation splits a mixture into just two groups — big and small. Desalting is group separation: a protein against salt, on a short Sephadex G-25 column, done in minutes. A big sample is fine here (up to 30% of the bed volume) because only two groups must part, so even broad zones stay separate. Fractionation spreads a mixture out by size across the whole column: many peaks, each a different size, collected in many tubes. It needs a long column and a small sample (2% of the bed volume), because a fat sample plug spreads as it travels and neighbouring peaks merge. More questions on the water-based method are in the gel filtration questions post.
The instrument: pump, column, detector, fraction collector
A modern gel filtration system (an FPLC — fast protein liquid chromatography — system) has four parts, and each one has a single job:
- Pump. Pushes buffer through the column at a slow, steady, pulse-free rate. Gel filtration flow is slow on purpose: molecules need time to diffuse into and out of the pores, and a fast flow broadens the peaks. For example, a Superdex 200 Increase 10/300 column is typically run at about 0.5 mL per minute.
- Column. A glass or steel tube holding the packed gel bed, with a filter (frit) at each end to keep the beads in and a flow adaptor that spreads the sample evenly across the top of the bed — the same packed-tube idea as in column chromatography.
- Detector. Watches the liquid coming out and draws the chromatogram. Proteins are followed by ultraviolet absorbance at 280 nm (the amino acids tryptophan and tyrosine absorb there); nucleic acids at 260 nm; peptides with no tryptophan or tyrosine at 215 nm, where the peptide bond itself absorbs; and colourless polymers by a refractive-index detector. A MALS detector (multi-angle light scattering) measures absolute molecular weight directly, with no standards at all.
- Fraction collector. Catches the eluate in a row of test tubes, one fraction after another, so each peak can be kept, tested and used. Without it, the separation would be visible on screen but lost down the drain.

The photograph above shows a fast protein liquid chromatography (FPLC) apparatus from 1993, built by Pharmacia Biotech — pump units, a UV monitor and a fraction collector carousel at the bottom left, with buffer bottles on top. This exact instrument is now on display at the Science Museum in London: it is a museum piece, not a working laboratory run, but every part of a modern FPLC system is already here — pump, column position, detector and collector. What the photograph does not show is a run in progress: the bottles are empty and the collector holds no tubes.
Desalting and buffer exchange, step by step
Desalting is the most-used gel filtration job, and the easiest to understand: a protein in salty water is poured onto a short Sephadex G-25 column, and the protein comes out in clean buffer while the salt stays behind. The protein is too big for the G-25 pores, so it rushes out at V0. The salt ions are tiny, enter every pore, and trail behind at Vt. One short column — a few minutes — replaces hours of dialysis, and the protein is collected in whatever buffer the column was equilibrated with. That second fact is buffer exchange: equilibrate the column in the new buffer, and the protein comes out dissolved in the new buffer, its old buffer left behind in the pores.
The same idea scales down to a spin column: a small pre-packed G-25 cartridge that is spun in a centrifuge for a minute instead of being run on a pump. Teaching and research laboratories desalt hundreds of small samples this way every week — after protein precipitation, before mass spectrometry, and whenever a sample must change buffers without being diluted by dialysis.
Worked example — desalting on a PD-10 column. A PD-10 desalting column holds 8.3 mL of Sephadex G-25 gel. The protocol is fixed:
- Equilibrate. Wash the column with the new buffer (about 25 mL) so the gel is sitting in the buffer the protein must end up in.
- Load. Add at most 2.5 mL of the protein sample (in its old, salty buffer) and let it sink into the bed.
- Elute. Add 3.5 mL of the new buffer. The protein — too big for the pores — comes out in that 3.5 mL, desalted and in the new buffer.
- Discard the rest. The salt is still inside the column, in the pores. It comes out only with further buffer, and it is thrown away.
Two numbers matter here and examiners test both: 2.5 mL in, 3.5 mL out. The protein is collected in a slightly larger volume than it went in, so it is a little more dilute — the price of a one-minute desalting.

The photograph above shows a Cytiva PD SpinTrap G-25 desalting spin column, photographed on 1 cm grid paper with its own label (part number 28918004). The small clear cartridge at the top holds Sephadex G-25, and it sits in its collection tube: a protein sample spun through it for a minute comes out desalted. What the photograph does not show is the separation happening inside: the cartridge looks like an empty plastic tube, and the work is done by the invisible beads packed within it. Photograph: Photocyte, Wikimedia Commons, CC BY-SA 4.0.
Procedure: running a gel filtration column step by step
- Swell and pack the gel. Soak the dry gel in buffer until it is fully swollen (dry Sephadex swells several-fold), then pour it into the column in one smooth pour as a slurry and let it settle into an even bed with no bubbles, cracks or dry patches.
- Equilibrate the column. Pump at least two bed volumes of running buffer through the bed, so the gel, the pH and the salt concentration are the same everywhere. A column that is not equilibrated gives distorted peaks. Degas the buffer first, so no air bubbles form in the bed.
- Prepare the sample. Dissolve the sample in the running buffer itself (or a very similar one), remove any particles by centrifugation or by filtering through a 0.22 micrometre filter, and keep the volume small — no more than about 2% of the bed volume for a high-resolution run (up to 30% is fine for desalting).
- Load the sample. Layer the sample gently on top of the bed as a thin, even band. Do not disturb the bed surface: a dent in the bed becomes a channel, and a channel splits the peaks.
- Elute. Pump buffer at a slow, constant flow rate and collect the eluate in fractions. Watch the detector: the first peak is the void volume, and the run ends when the smallest molecules have eluted at Vt.
- Analyse the fractions. Test the fractions (UV absorbance at 280 nm, an activity assay, or gel electrophoresis) to find which tubes hold the target molecule, then pool them. The pooled fractions are more dilute than the loaded sample — concentration afterwards is normal.
- Wash and store the column. Wash with buffer, then store the gel wet (usually in buffer with a little preservative such as 20% ethanol). A dried-out bed cracks and is ruined; a frozen bed breaks.
Reading a chromatogram: the calibration curve
A chromatogram is a graph of detector signal against elution volume. Each peak is one size-group, and its top marks that group's Ve — the position is like the Rf value in paper chromatography: a number that identifies the molecule. The first peak sits at V0 (everything too big for the pores), the last at Vt (everything small enough for every pore), and the peaks in between sit in order of decreasing size. Two numbers are read from the graph: the position of each peak (Ve, for identification and molecular-weight estimation) and the area under each peak (for how much of each size is present).
Molecular-weight estimation needs a calibration curve. Standards of known molecular weight are run on the same column, their Kav values are calculated, and Kav is plotted against the logarithm of molecular weight. Inside the fractionation range the plot is a straight line — and an unknown's molecular weight is read from the line using its own Kav. The result is an apparent molecular weight: exact for a globular protein shaped like the standards, approximate (often within about ±10%) for anything else, and misleading for a long, thin molecule, which behaves bigger than its mass.
Worked example — estimating a molecular weight. A column has V0 = 30 mL and Vt = 110 mL. Four standards are run:
- 150 kDa protein, Ve = 42 mL → Kav = (42 − 30) ÷ 80 = 0.15
- 75 kDa protein, Ve = 54 mL → Kav = (54 − 30) ÷ 80 = 0.30
- 30 kDa protein, Ve = 70 mL → Kav = (70 − 30) ÷ 80 = 0.50
- 12 kDa protein, Ve = 86 mL → Kav = (86 − 30) ÷ 80 = 0.70
Plotting Kav against log(MW) gives a straight line, approximately Kav = −0.50 × log(MW) + 1.24. An unknown protein elutes at Ve = 62 mL, so its Kav = (62 − 30) ÷ 80 = 0.40. From the line, log(MW) = (1.24 − 0.40) ÷ 0.50 = 1.68, so MW = 10^1.68 ≈ 48 kDa. That is the protein's apparent molecular weight — the mass of a globular protein that would elute at the same volume.

The photograph above is a real chromatogram from a Sephadex G-50 Superfine column: the UV absorption (E at 254 nm) of an Arabidopsis (a small plant) cell extract, plotted against elution volume in millilitres. The column held 500 mL of gel (700 mm long, 30 mm wide) and the buffer flowed at 12 mL per hour. The void volume is marked at about 120 mL, where the biggest metal-containing proteins come out (cadmium proteins 200 kDa, copper species 140 kDa, iron proteins 200 kDa). The big broad peaks after 350 mL hold the small things — proteins, peptides, carbohydrates and nucleic acids under 30 kDa. What the graph does not show is which peak is which protein: that is found afterwards, by testing the fractions. Photograph (chromatogram): Bernd Kastenholz, Wikimedia Commons, CC BY-SA 3.0.
Gel filtration in protein purification
No single method purifies a protein. A purification scheme uses several methods in order, each separating by a different property, so a contaminant that survives one step is caught by the next. Gel filtration is the last step — the polishing step — because it is gentle and it puts the protein into its final buffer.
Worked example — a purification table. A student purifies an enzyme from a cell extract. The numbers are an illustrative example (every purification gives different numbers), and they show how the table is read:
| Step | Total protein | Total activity | Specific activity | Yield | Fold purification |
|---|---|---|---|---|---|
| Crude extract | 500 mg | 1,000 U | 2 U/mg | 100% | 1 |
| Ammonium sulfate precipitation | 120 mg | 800 U | 6.7 U/mg | 80% | 3.3 |
| Ion exchange chromatography | 25 mg | 600 U | 24 U/mg | 60% | 12 |
| Gel filtration (polishing) | 10 mg | 500 U | 50 U/mg | 50% | 25 |
Read the table from left to right. Specific activity is total activity divided by total protein — it measures purity. Yield is the activity still present, as a percentage of the starting activity — it measures how much was lost. Fold purification is the specific activity of a step divided by the specific activity of the crude extract. After gel filtration the enzyme is 25 times purer than the crude extract (50 ÷ 2), and half the activity survives (500 ÷ 1,000). The trade is visible: every step gains purity and loses some product. Gel filtration's own contribution is the last line: it removes aggregates and fragments, desalts the sample, and delivers the protein in its final buffer.
Uses of gel filtration chromatography
Gel filtration is often paired with differential centrifugation, which separates cell parts by spinning before gel filtration polishes the proteins, and the purified proteins and DNA then go on to genetic engineering.
- Protein purification (polishing). The final step after affinity chromatography or ion exchange chromatography: aggregates and fragments are removed, and the pure protein comes out in its final buffer.
- Desalting and buffer exchange. Removing ammonium sulfate after precipitation, or moving a protein into a new buffer, on Sephadex G-25.
- Molecular-weight estimation. Finding an unknown protein's apparent molecular weight from a calibration curve of standards.
- Finding whether proteins stick together. Two proteins that bind form a complex bigger than either one, so the mixture elutes earlier than both alone — gel filtration can show that an interaction exists (but not how strong it is, or the exact ratio).
- Detecting aggregation. In biopharmaceutical quality control, a monoclonal antibody that has clumped into aggregates elutes early as a separate peak near V0 — gel filtration is the routine test for it.
- Removing small contaminants. Free dye from labelled protein, unreacted cross-linker from a conjugate, or small-molecule inhibitors from an enzyme preparation — all by the same size gap.
- Virus and plasmid purification. Very large particles are excluded from every pore and elute at V0, cleanly separated from small contaminants, on wide-pore gels such as Sepharose 6B — plasmids for bacterial genetic recombination are prepared this way.
- Polymer analysis (GPC). Measuring the molecular-weight distribution of synthetic polymers: the average masses Mn and Mw and the polydispersity (how broad the distribution is). The cells whose proteins gel filtration purifies are the starting point of all of this work.
Gel filtration vs other chromatography
| Method | Separates by | Do molecules bind? |
|---|---|---|
| Gel filtration | Size (hydrodynamic volume) | No — the gel is inert |
| Ion exchange | Electric charge | Yes — opposite charges attract |
| Affinity | Specific binding (a ligand partner) | Yes — very specific and strong |
| Paper / thin-layer | Partition between two phases | Weakly — adsorption to cellulose/silica |
| Column (adsorption) | Adsorption and polarity | Yes — to the solid packing |
The table explains why laboratories use gel filtration together with other methods rather than instead of them. Paper chromatography and thin-layer chromatography separate small molecules by partition; affinity chromatography captures one protein out of a crude mixture; ion exchange then separates the survivors by charge; gel filtration finishes the job by removing aggregates and putting the protein in its final buffer. Each method separates by a different property, so a contaminant that survives one step is caught by the next. A purification that used gel filtration alone would leave every molecule of similar size together — which is why the "one-step purification" is a trap, not a plan.
Troubleshooting and safety
| Problem | Likely cause | Fix |
|---|---|---|
| Broad, overlapping peaks | Sample volume too large; flow too fast | Load ≤2% of the bed volume; slow the flow |
| Split (double) peaks | Cracked bed, channelling, air bubble | Repack the column; degas the buffer |
| Everything elutes at V0 | Gel exclusion limit too low for the sample | Choose a gel with bigger pores (higher G-number) |
| Everything elutes at Vt | Gel pores too large; molecules too small for the gel | Choose a gel with smaller pores (lower G-number) |
| Peak after Vt | Adsorption to the gel — the molecule is sticking | Add salt (0.1–0.5 M) to the buffer; change the pH |
| Pressure rises steeply | Clogged frit or filter; compressed or dirty gel | Filter the sample; clean or replace the frit; repack |
Safety. Gel filtration itself is one of the safest chromatography methods — ordinary buffers, room temperature, no heat — but the laboratory around it is not. Acrylamide monomer (for polyacrylamide gels) is toxic and must be handled with gloves in a fume hood; organic solvents for GPC (such as tetrahydrofuran) are flammable and form explosive peroxides on storage; pressurised glass columns must be shielded and never run above their rated pressure; and biological samples must be treated as potentially infectious. Wash the column after every run, store the gel wet in preservative, and never let a packed bed dry out or freeze.
10 exam traps
- Largest first. In gel filtration the biggest molecules elute first — the opposite of paper and thin-layer chromatography, where the smallest and most soluble travel furthest. If you write "smallest first", the mark is lost.
- Size, not mass. Gel filtration separates by hydrodynamic volume. A long, thin protein — or a sugar-coated glycoprotein — elutes before a compact protein of the same mass. Any question that says "same mass, so same elution volume" is a trap.
- Kav = 0 is V0, Kav = 1 is Vt. Mix them up and every calculation inverts. Kav = 0 means fully excluded; Kav = 1 means fully included.
- Gel filtration is aqueous; GPC is organic. The names describe the solvent, not different principles. "Gel filtration of polystyrene in tetrahydrofuran" is a contradiction — that is GPC.
- Sample volume depends on the job. Fractionation needs ≤2% of the bed volume; desalting allows up to 30%. A question that applies one rule to the other job is a trap.
- Above the exclusion limit, everything elutes together. Two proteins both larger than the limit cannot be separated on that gel, however different their masses are. Pick a bigger-pore gel or accept one peak.
- G-25 cannot separate two proteins. Sephadex G-25 is for desalting (protein versus salt), not for separating proteins from each other — both proteins sit above its exclusion limit and elute together at V0.
- Nothing binds in gel filtration. A peak after Vt means adsorption — a fault, not the mechanism. If a protein never comes out, suspect unwanted binding — do not explain it as "strong separation".
- Apparent molecular weight, not absolute. A calibration curve compares the unknown with globular standards. A long, thin or sugar-coated protein reads too high, so the number is approximate — about ±10% for globular proteins.
- Gel filtration is low resolution. It cannot separate similar sizes, and it cannot purify a protein in one step. In a purification scheme it is the polishing or desalting step — never the only step. For more practice on the paper method, try the paper chromatography MCQs.
Key points
- Gel filtration is size exclusion chromatography in water: porous gel beads separate molecules by hydrodynamic volume — largest first (at V0), smallest last (at Vt).
- Gel filtration is SEC in water-based buffers; gel permeation chromatography (GPC) is SEC in organic solvents.
- V0 is the void volume (liquid between beads, measured with Blue Dextran); Vt is the total bed volume (πr²h); Ve is a molecule's elution volume.
- Kav = (Ve − V0) ÷ (Vt − V0), between 0 and 1: 0 means fully excluded, 1 means fully included.
- Group separation (desalting) splits big from small on a short column with up to 30% sample; fractionation spreads many sizes on a long column with ≤2% sample.
- A calibration curve of Kav against log(molecular weight) is a straight line inside the fractionation range, and it gives an unknown's apparent molecular weight.
- Sephadex G-25 desalts; higher G-numbers (G-50 to G-200) separate bigger proteins; Sepharose 6B handles the largest molecules; Superdex and Sephacryl give sharper peaks at higher flow.
- Keep the sample at or below 2% of the bed volume for fractionation, keep the flow slow, equilibrate the column first, dissolve the sample in the running buffer, and store the bed wet.
- Gel filtration is gentle (molecules come out unchanged) but low in resolution — it polishes and desalts, it does not purify in one step.
Frequently asked questions
What is the difference between gel filtration and size exclusion chromatography?
There is no difference in principle: gel filtration is the name for size exclusion chromatography when the mobile phase is water-based (a buffer). When the mobile phase is an organic solvent, the same technique is called gel permeation chromatography (GPC). All three names describe separation by size on porous beads.
Why do big molecules come out first in gel filtration?
Big molecules cannot fit into the pores of the gel beads, so they travel only in the liquid between the beads — the shortest route through the column — and elute first, at the void volume V0. Small molecules diffuse into the pores and take a much longer, winding route, so they elute last.
What is the difference between group separation and fractionation?
Group separation splits a mixture into two groups — big and small — on a short column; desalting is group separation (protein versus salt). Fractionation spreads a mixture out by size across a long column into many fractions, so several proteins of different sizes can be collected separately. Group separation allows a sample up to 30% of the bed volume; fractionation needs 2% or less.
How does a PD-10 column desalt a protein?
A PD-10 column holds Sephadex G-25. At most 2.5 mL of protein sample is loaded, then 3.5 mL of the new buffer is added. The protein is too big for the G-25 pores, so it rushes out at the void volume in the new buffer; the salt ions are tiny, enter the pores, and come out later. The protein is collected desalted in minutes.
Can gel filtration find the molecular weight of an unknown protein?
Yes, approximately. Standards of known molecular weight are run on the same column, Kav is plotted against log(molecular weight) to give a straight calibration line, and the unknown's molecular weight is read from the line using its own Kav. The answer is an apparent molecular weight — accurate for globular proteins shaped like the standards, approximate (about ±10%) otherwise, and misleading for long, thin molecules, which behave bigger than their mass.
Why is my gel filtration peak broad or split?
Broad peaks usually mean the sample volume was too large (keep it at or below 2% of the bed volume for fractionation) or the flow was too fast. A split peak usually means a cracked bed, channelling, or an air bubble — the sample took two different paths. Repack the column, degas the buffer, and check the sample is dissolved in the running buffer.
Is gel filtration used in industry?
Yes, widely. In biopharmaceutical manufacturing gel filtration is the routine quality-control test for antibody aggregation; in polymer factories GPC measures the molecular-weight distribution of every batch of plastic; and in research laboratories gel filtration desalts, buffer-exchanges and polishes proteins every day. It is one of the few techniques used unchanged from a school teaching laboratory to a drug factory.
Practice MCQs
Choose one answer for each question, then open it to see the answer and the explanation.
Q1. What is gel filtration chromatography?
A. A technique that separates molecules by their solubility in oil and water, using a two-phase solvent
B. A technique that separates molecules by their electric charge, using a column packed with charged beads
C. A technique that separates molecules by their boiling point, using a heated column
D. Size exclusion chromatography with a water-based buffer as the mobile phase, used to separate proteins and other water-soluble molecules by size
Answer: D. Size exclusion chromatography with a water-based buffer as the mobile phase, used to separate proteins and other water-soluble molecules by size
Gel filtration is size exclusion chromatography in water: the column is packed with porous gel beads in a buffer, large molecules cannot enter the pores and come out first, and small molecules wander into the pores and come out last. Proteins come out still folded and active, which is why the method is the standard way to clean up and desalt a protein.
Q2. Why is the technique in this lesson called 'gel filtration' and not 'gel permeation'?
A. Because it filters cells out of the sample and keeps only proteins
B. Because the sample is filtered through paper before it is loaded
C. Because the gel is made of dextran and not of agarose
D. Because the mobile phase is a water-based buffer; 'gel permeation' is the name for the same technique with an organic solvent
Answer: D. Because the mobile phase is a water-based buffer; 'gel permeation' is the name for the same technique with an organic solvent
The name describes the solvent, not a different principle. With a water-based buffer the technique is called gel filtration (the protein world); with an organic solvent such as tetrahydrofuran it is called gel permeation chromatography, GPC (the polymer world). Both are size exclusion chromatography on porous beads.
Q3. What is the difference between group separation and fractionation in gel filtration?
A. Fractionation separates only two groups, while group separation gives many fractions
B. Group separation splits a mixture into two groups (large and small) on a short column; fractionation spreads a mixture out by size across a long column into many fractions
C. They are the same job with two different names
D. Group separation needs a long column and fractionation works on a short one
Answer: B. Group separation splits a mixture into two groups (large and small) on a short column; fractionation spreads a mixture out by size across a long column into many fractions
The two jobs ask different things of the column. Desalting is group separation: protein versus salt, two groups, done on a short Sephadex G-25 column in minutes. Separating several proteins of different sizes is fractionation: it needs a long column so the sizes can spread out into many fractions.
Q4. For desalting a protein on Sephadex G-25, how large may the sample be?
A. About half of the bed volume, so the column is well filled
B. Equal to the void volume, so the sample fills the spaces between the beads
C. No more than about 2% of the bed volume, or the peaks will overlap
D. Up to about 30% of the bed volume (20–30% is fine, because only two groups must part)
Answer: D. Up to about 30% of the bed volume (20–30% is fine, because only two groups must part)
A big sample is allowed for desalting because only two groups must part — the big protein and the small salt — so even broad zones stay separate. For fractionation, where neighbouring proteins must part, the sample must stay at or below about 2% of the bed volume.
Q5. A PD-10 desalting column is loaded with 2.5 mL of protein sample. How is the desalted protein collected?
A. By adding 3.5 mL of the new buffer and collecting the protein that comes out at the void volume
B. By boiling the column and collecting the vapour
C. By spinning the column dry and scraping the protein off the gel
D. By adding 25 mL of buffer and collecting everything that comes out
Answer: A. By adding 3.5 mL of the new buffer and collecting the protein that comes out at the void volume
The PD-10 protocol is fixed: at most 2.5 mL of sample in, 3.5 mL of new buffer to elute. The protein is too big for the G-25 pores, so it rushes out at the void volume in the new buffer; the salt stays in the pores and comes out later.
Q6. What is the fractionation range of Sephadex G-75 for globular proteins?
A. About 3,000 to 80,000 Da
B. About 5,000 to 600,000 Da
C. About 1,000 to 5,000 Da
D. About 4,000 to 150,000 Da
Answer: A. About 3,000 to 80,000 Da
Sephadex G-75 separates globular proteins between about 3,000 Da and 80,000 Da (its exclusion limit). A protein outside this range cannot be resolved on G-75: above 80,000 Da it elutes at V0 with everything else big, so pick a higher G-number.
Q7. Which gel would you choose to separate very large molecules such as viruses or plasmids?
A. Sephadex G-50
B. Sephadex G-25
C. Sepharose 6B (wide-pore agarose, fractionation range about 10,000 to 4,000,000 Da)
D. Bio-Gel P-2
Answer: C. Sepharose 6B (wide-pore agarose, fractionation range about 10,000 to 4,000,000 Da)
Very large particles need very wide pores. Sepharose 6B is agarose with big pores, so viruses, plasmids and huge protein complexes can enter them and be spread out. Sephadex G-25 and G-50 have tiny pores — a virus would be excluded from both and elute at V0.
Q8. Sephacryl is a gel made of allyl dextran cross-linked with bisacrylamide. What is its practical advantage?
A. It works only for DNA and never for proteins
B. It is rigid, so it survives higher flow rates than soft Sephadex and gives sharper peaks
C. It binds proteins strongly, so nothing is lost in the column
D. It dissolves in water, so the column never needs washing
Answer: B. It is rigid, so it survives higher flow rates than soft Sephadex and gives sharper peaks
Sephadex is soft and compresses under pressure, which limits how fast the buffer can be pumped. Sephacryl beads are rigid, so the column can be run faster without the bed squeezing shut — useful when many samples must be processed in a day.
Q9. A gel filtration column has Vt = 110 mL and V0 = 30 mL. A protein elutes at Ve = 70 mL. What is its Kav?
A. 0.64
B. 0.27
C. 0.50
D. 0.36
Answer: C. 0.50
Kav = (Ve − V0) ÷ (Vt − V0) = (70 − 30) ÷ (110 − 30) = 40 ÷ 80 = 0.50. The protein can enter half of the pore volume.
Q10. A protein has Kav = 0.40 on a gel filtration column. What does this number mean?
A. The protein can enter 40% of the pore volume
B. The protein elutes at the void volume, V0
C. 40% of the protein is lost inside the column
D. The protein enters every pore and elutes at Vt
Answer: A. The protein can enter 40% of the pore volume
Kav is the fraction of the pore volume a molecule can enter: Kav = 0 means fully excluded (elutes at V0), Kav = 1 means it enters every pore (elutes at Vt). Kav = 0.40 means the protein can enter 40% of the pores — it is a middle-sized molecule for this gel.
Q11. Four standards give a straight calibration line Kav = −0.50 × log(MW) + 1.24 (MW in kDa). An unknown protein has Kav = 0.40. What is its approximate molecular weight?
A. About 75 kDa
B. About 30 kDa
C. About 48 kDa
D. About 12 kDa
Answer: C. About 48 kDa
From the line, log(MW) = (1.24 − 0.40) ÷ 0.50 = 1.68, so MW = 10^1.68 ≈ 48 kDa. This is the protein's apparent molecular weight — the mass of a globular protein that would elute at the same volume.
Q12. Which small molecule is used to measure the total volume Vt of a gel filtration column?
A. Acetone (a tiny molecule that enters every pore and elutes at Vt)
B. Blue Dextran 2000
C. Haemoglobin
D. Sephadex G-25
Answer: A. Acetone (a tiny molecule that enters every pore and elutes at Vt)
Vt is measured with a molecule small enough to enter every pore — acetone is the usual choice. Blue Dextran 2000 does the opposite job: it is far too large to enter any pore, so it measures the void volume V0.
Q13. A peptide with no tryptophan or tyrosine is almost invisible at 280 nm. How can it still be followed as it elutes?
A. By a conductivity meter, because peptides carry no charge
B. By a pH meter, because peptides change the pH as they elute
C. By absorbance at 215 nm, where the peptide bond itself absorbs
D. By absorbance at 260 nm, where peptides absorb most strongly
Answer: C. By absorbance at 215 nm, where the peptide bond itself absorbs
Proteins are followed at 280 nm only because tryptophan and tyrosine absorb there. A peptide without them is nearly invisible at 280 nm, but every peptide bond absorbs at 215 nm, so the detector is switched to 215 nm. Nucleic acids are followed at 260 nm.
Q14. Where does gel filtration usually sit in a protein purification scheme?
A. As the only step, because it purifies a protein completely on its own
B. Instead of centrifugation, to spin the cell debris down
C. First, before the cells are even broken open
D. Last, as the polishing step — after ammonium sulfate precipitation and ion exchange or affinity chromatography
Answer: D. Last, as the polishing step — after ammonium sulfate precipitation and ion exchange or affinity chromatography
Gel filtration is low in resolution, so it cannot purify a protein in one step. It is used at the end: ion exchange or affinity chromatography captures the protein, and gel filtration polishes it — removing aggregates and fragments and putting it into its final buffer.
Q15. In a purification table, how is the 'fold purification' of a step calculated?
A. Total activity ÷ volume of the sample
B. Total protein after the step ÷ total protein before the step
C. Percentage yield ÷ fold purification
D. Specific activity after the step ÷ specific activity of the crude extract
Answer: D. Specific activity after the step ÷ specific activity of the crude extract
Specific activity is total activity divided by total protein. Fold purification is how many times purer the protein has become: specific activity after the step divided by specific activity of the crude extract. In the worked example, gel filtration gives 50 U/mg against 2 U/mg in the crude extract — a 25-fold purification.
Q16. A 50 kDa protein elutes from a gel filtration column at the volume expected for a 100 kDa protein. What does this suggest?
A. The buffer is wrong and the run must be repeated
B. The protein has lost half its mass in the column
C. The protein is a dimer (two 50 kDa units stuck together) in solution — or it is an elongated molecule
D. The column is broken and must be thrown away
Answer: C. The protein is a dimer (two 50 kDa units stuck together) in solution — or it is an elongated molecule
Gel filtration measures the size of the species in solution, not the mass of one chain. A 50 kDa chain that pairs up into a dimer behaves as a 100 kDa particle and elutes early. Running the same sample on SDS-PAGE (which breaks the dimer apart) would show the 50 kDa chain and confirm it.
Q17. Why is a sample filtered or centrifuged before it is loaded on a gel filtration column?
A. To remove the buffer the protein is dissolved in
B. Particles and aggregates clog the filter at the top of the bed, raise the pressure and distort the peaks
C. To make the proteins smaller so they enter the pores
D. To warm the sample to the temperature of the running buffer
Answer: B. Particles and aggregates clog the filter at the top of the bed, raise the pressure and distort the peaks
Any particle in the sample lands on the filter (frit) at the top of the bed and blocks it, so the pressure rises and the sample zone distorts. Centrifuging or filtering the sample through a 0.22 micrometre filter first keeps the bed clean.
Q18. What happens if a packed gel filtration bed is allowed to dry out?
A. The gel swells even more and the resolution improves
B. The proteins bind to the dry gel and can be washed off later
C. Nothing happens; a dry bed re-wets perfectly
D. The bed cracks and channels form, so the sample takes different paths and the peaks split — the column is usually ruined
Answer: D. The bed cracks and channels form, so the sample takes different paths and the peaks split — the column is usually ruined
A gel bed must stay wet. Once it dries, it shrinks and cracks, and buffer then races down the cracks (channelling) instead of flowing evenly through the bed. The sample splits into two streams and the peaks split. Store columns wet, in buffer with preservative.
Q19. What material did Lathe and Ruthven use in 1955 for the first gel filtration separation of proteins?
A. Swollen maize starch gels
B. Agarose beads
C. Silica gel
D. Cross-linked dextran (Sephadex)
Answer: A. Swollen maize starch gels
Lathe and Ruthven separated proteins on swollen starch gels in 1955 — the first gel filtration. Four years later, in 1959, Porath and Flodin introduced cross-linked dextran (Sephadex) and coined the term 'gel filtration', which made the technique routine.
Q20. Why must dry Sephadex be soaked in buffer for hours before the column is packed?
A. Soaking sterilises the gel before use
B. Soaking colours the beads so the bed can be seen
C. Dry Sephadex swells several-fold in water; packing it dry and then wetting it would crack and distort the bed
D. Soaking dissolves the dextran so it can be poured
Answer: C. Dry Sephadex swells several-fold in water; packing it dry and then wetting it would crack and distort the bed
Dry Sephadex beads swell several times their volume in water. If they are packed dry and then wetted, they swell inside the column, squeeze each other, crack the bed and block the flow. The gel is always swollen fully first, then poured as a slurry.
Quiz: test yourself
Answer all 20 questions, then press Submit. The quiz shows your score and explains every answer. Press Reset to try again.
Continue learning
- Size Exclusion Chromatography: Principle and Uses — the general lesson on the same technique, with Kav worked examples.
- Gel Filtration Chromatography: Principles & MCQs — more questions on the gel method.
- Gel Filtration Chromatography Quiz — an online quiz on the gel method.
- Paper Chromatography: Separating Mixtures on Paper — separation by partition on paper, with Rf values.
- Revealing the Potential of Thin Layer Chromatography — the fast, sharp cousin of the paper method.
- Column Chromatography: Principles of Separation — the same separation inside a packed tube, for purification.
- Affinity Chromatography: Exploring Molecular Interactions — separation by a molecule's specific partner.
- Ion Exchange Chromatography: Separating Molecules by Charge — separation by electric charge.
- Rf Values in Chromatography: Formula, Pigments and Quiz — the paper-chromatography number, worked out step by step.
- Exploring the World of Chromatography: Principles, Applications, and Types — the whole chromatography family in one place.
- Differential Centrifugation: Principle, RCF Formula, Rotors and Organelle Separation — separating cell parts by spinning instead of by size.
- Paper Chromatography MCQs with Answers — 20 more questions on the paper method.
- Micrometry: Measuring Cells with Stage and Ocular Micrometers — measuring small things accurately.
- Cell Structure: The Building Blocks of Life — the cells whose proteins gel filtration purifies.
- Genetic Engineering: An Introduction — where purified proteins and DNA go next.
Find this post in the course guide: Botany Laboratory Techniques.
Sources
- LibreTexts — Gel Exclusion Chromatography (Ahern and Rajagopal) — principle, exclusion limit, and the V0 ≈ one-third rule.
- LibreTexts — SEC Separations Module — theory, pore size and gel materials for protein SEC.
- CASRAI — SEC Calibration Curve: Kav Formula and Example — V0, Vt, Ve, Kav, and the Kav 0.1–0.7 linear window.
- Springer Nature Experiments — Gel-Filtration Chromatography — gel filtration protocol for separating proteins and peptides by size.
- Khan Academy — A Closer Look at Types of Chromatography — size exclusion principle, molecular-weight estimation, desalting and buffer exchange.
- BYJU'S — Classification of Chromatography — SEC named as separation by hydrodynamic volume.
- NPTEL — Gel Filtration Chromatography (Lecture 32) — history (1955 starch gels; Porath and Flodin) and Kd/Kav volumes.
- ChemGuide — Paper Chromatography — the partition method gel filtration is most often compared with.
Courses
Diversity of Plants (BOT-303)
Pteridophytes & Gymnosperms (BOT-509)
Phycology & Bryology
Plant Tissue Culture
Plant Biochemistry II
Plant Physiology I
Plant Physiology II
Mycology & Plant Pathology
Microbiology & Virology
Cell Biology, Genetics & Evolution
Mycology (BOT-405)
Genetics I
Biochemistry
Plant Taxonomy & Systematics
Diversity of Vascular Plants
Advanced Plant Ecology
Plant Ecology II
Biodiversity & Conservation
Functional Biology
Botany Laboratory Techniques
Laboratory Techniques
Topics
Microbiology
Cell Biology
Practice
Study Tools
0 Comments
Have a biology question or spotted an error?
Send feedback to PreachBio →