Glassware Cleaning MCQs: Questions, Answers and Explanations
Level: GCSE and A-level Biology, AP Biology and IB Biology, with first-year university extension marked clearly. This lesson teaches everything the 20 multiple choice questions and the 20-question quiz on glassware cleaning test: why clean glass matters, the two kinds of glass, safety, the six steps of the general wash, detergents, the acid wash, the base bath, rinsing and the water-break test, drying and storage, and the special cases of volumetric glassware, cuvettes and contaminated glassware. For the full lesson, with every step explained in depth, read the full lesson on glassware cleaning first. This page is the shorter companion: it teaches what the questions test, then the questions follow.
What you will learn: why dirty glassware gives wrong results; the difference between borosilicate and soda-lime glass; the safety rules for acids and bases; the six steps of the general wash; how detergents work and which ones to use; when to use an acid wash and when to use a base bath; what never to do when cleaning glassware; how to rinse and how to test glassware with the water-break test; how to dry, check and store clean glassware; and how to handle volumetric glassware, cuvettes and contaminated glassware.
Why clean glassware matters for good results
A dirty flask can ruin an experiment before it starts. A thin film of grease, a drop of old acid, or a few salt crystals on the wall of a beaker each change the result. Clean glassware is not about looking tidy. It is about getting results you can trust.
Take three examples. First, a titration (a method that finds the concentration of a solution by adding another solution drop by drop until the reaction is complete). If the burette (a long glass tube with a tap, used to add exact volumes) still holds drops of tap water, the acid inside is diluted and the titre (the volume used) comes out wrong. Second, an enzyme assay (a test that measures how fast an enzyme works). If the test tube still holds traces of detergent or metal, the enzyme slows down or stops, and the rate you measure is not the true rate. The enzymes lesson teaches how sensitive enzymes are to their conditions. Third, cell culture (growing living cells in a dish or flask). Dirty glass can kill the cells or let microbes grow in the dish. The cell signalling lesson and the stem cells lesson both depend on cells grown in clean glassware.
Residue also changes the solution a cell sits in. A trace of acid or base left on the glass changes the pH, and dissolved salts change the concentration outside the cell. The membrane transport lesson teaches how water and solutes move across the cell membrane when the solution outside changes. So a dirty flask does not only add dirt — it changes the experiment itself.
There are three good reasons to clean glassware well. Accuracy: clean glass gives true results. Safety: old chemicals left in glassware can react with the next chemical and cause harm. Long life: glassware that is cleaned gently and stored well lasts for years; glassware that is scrubbed with abrasives or heated wrongly cracks and must be thrown away.
Know your glass: borosilicate and soda-lime
There are two kinds of glass in the lab, and they behave very differently with heat. Know which one you are holding before you heat it, wash it in hot water, or put it in an oven.
Borosilicate glass (a heat-resistant glass made with boron oxide) is the lab standard. It is thick, heavy and strong. Its coefficient of thermal expansion (a number that says how much a material grows when it is heated) is only 3.3 × 10−6 per kelvin, which is very low. That means it barely grows when heated, so it survives a sudden change in temperature without cracking. Lab glass marked PYREX or DURAN, or marked "borosilicate 3.3", is this glass. You may heat borosilicate glass with a Bunsen flame, and you may put it in a drying oven.
Soda-lime glass (ordinary glass, made with soda and lime, like window glass) is thin, light and cheap. Its coefficient of thermal expansion is about 9 × 10−6 per kelvin — roughly three times that of borosilicate. It tolerates only about a 40 °C sudden change in temperature before it can crack. Never heat soda-lime glass. A useful warning: kitchen Pyrex sold in the USA is soda-lime glass, not lab glass. Lab PYREX is borosilicate; kitchen Pyrex is not the same thing.
Thermal shock (cracking caused by a sudden change in temperature) is the danger. When hot glass meets cold water, or cold glass meets a flame, one part grows faster than the rest and the glass cracks. Borosilicate resists this because it grows so little. Soda-lime does not.
How do you tell them apart? Read the mark on the glass. Borosilicate is usually marked "borosilicate 3.3", "PYREX" or "DURAN". It also feels thick and heavy. If there is no mark and you are not sure, treat the glass as soda-lime and never heat it. And remember: measuring cylinders and volumetric flasks are never heated at all, whatever glass they are made of — they are made for measuring, not for heating, as section 11 teaches.
Safety first: PPE, fresh air and never mixing chemicals
Cleaning glassware means handling chemicals that can burn skin, damage eyes and give off harmful fumes. The safety rules come before the cleaning, every time.
PPE (Personal Protective Equipment — the clothing and gear that protects you) is the first rule. Wear safety goggles, gloves, a lab coat and closed shoes. For an acid wash or a base bath, wear acid-resistant gloves, not thin disposable gloves. Acid-resistant gloves must be worn whenever you handle acids or bases, not only for one of them. Goggles must fit close to the face: ordinary glasses do not protect the eyes from splashes. The general laboratory safety rules teach the full PPE list, and the lab safety quiz and the lab safety MCQs test it.
Fresh air: do acid washes, base baths and any work with strong chemicals in a fume hood (a ventilated cabinet that pulls air and fumes away from you). Never lean into the hood, and keep the sash (the glass window) at the marked safe height. The biosafety cabinet lesson teaches how ventilated cabinets protect the worker.
Never mix cleaning chemicals in one bucket. Each solution stays in its own labelled container. Acid mixed with bleach makes chlorine gas, which is poisonous. Acid mixed with base in a bucket can boil and splash. The habit of mixing detergent, acid and base together in a cleaning bucket is dangerous and wrong — keep them separate and use them one at a time.
Never pipette by mouth. Mouth pipetting (sucking liquid up a pipette with your mouth) is banned in every laboratory. It is the most common route by which lab workers swallow poisons. Always use a pipette filler (a rubber bulb or a pump that draws the liquid up for you).
Before you start, know where the eyewash, the spill kit and the first-aid box are. If a chemical splashes in your eyes, wash them at the eyewash for at least 15 minutes and tell your teacher at once. If acid or base touches your skin, wash with plenty of running water. Label every bath and bottle with the chemical name and the date, so nobody picks up the wrong one. Before you use any cleaning solution on a piece of glassware, check that the solution is safe for that glassware: the wrong cleaner can damage the glass or react with what is left inside it.
The general wash, step by step
Most glassware needs only the general wash. It has six steps, and the order matters. Each step has a job, and skipping one leaves the next one unable to work.
Step 1 — Pre-rinse with tap water. WHAT: rinse the glassware with tap water as soon as you finish using it. HOW: swirl tap water round the inside and tip it out. WHY: the pre-rinse removes loose particles and old solution before they dry on. This is the step that removes loose bits — not the detergent wash. If residue dries on, it is far harder to remove later. Tap water is also the water used for pre-soaking heavily soiled glassware before the detergent soak.
Step 2 — Soak in warm detergent solution. WHAT: leave the glassware in a warm solution of laboratory detergent. HOW: use Decon 90 at 2–5% in water and soak for 2 to 24 hours at 40–50 °C, or Alconox at 1% (10 g per litre) in warm water at about 50 °C. Heavily soiled glassware soaks overnight. WHY: warm water and detergent loosen grease and dried-on residue so the brush can remove it. Always follow the maker's instructions on the bottle.
Step 3 — Scrub with the right brush. WHAT: scrub every surface, inside and out, with a brush. HOW: use a soft brush for beakers and flasks and a long thin brush for narrow necks such as burettes. A burette is a long narrow tube, so only a long thin brush reaches the bottom. WHY: the brush removes the loosened residue that soaking alone cannot shift. The brush itself must be clean and free of grit, or it will scratch the glass. Never force a brush into a narrow neck — if it does not fit, soak longer instead.
Step 4 — Rinse with tap water. WHAT: rinse the soap and loosened dirt away with tap water. HOW: rinse several times, swirling the water over every surface. WHY: tap water is cheap and removes most of the detergent. But tap water is not the last rinse — it leaves salts behind, as section 9 teaches.
Step 5 — Final rinse with distilled water. WHAT: rinse three or four times with distilled water (water with its dissolved salts removed by boiling and condensing) or deionised water (water with its charged particles removed). HOW: use a wash bottle to squirt distilled water over every inside surface, then tip it out. WHY: distilled water leaves nothing behind when it dries, so the glass is truly clean.
Step 6 — Dry upside down and inspect. WHAT: let the glassware dry upside down on a rack or pegs, then check it. HOW: hold it up to the light and run the water-break test from section 9. WHY: drying upside down lets water drain out and keeps dust out, and the check proves the wash worked. If the test fails, wash the piece again from step 2.
Watch the wash in six steps. Press a step to follow one beaker through the general wash.
Follow one beaker through the general wash — pre-rinse, soak, scrub, tap rinse, distilled rinse, then dry and check.
Detergents: how soap lifts grease
A detergent is a surfactant (a chemical that helps water spread out and grab grease). Water alone cannot lift grease, because grease and water do not mix. A surfactant has two ends: one end grabs grease, the other end grabs water. The grease is pulled off the glass, wrapped in tiny parcels of detergent, and washed away with the water. So the detergent wash removes grease and dried-on residue — it does not remove loose particles, because the pre-rinse already did that job.
Laboratory detergents are made for this job. Decon 90 is used at 2–5% in water, with a soak of 2 to 24 hours at 40–50 °C depending on how dirty the glassware is. Alconox is used at 1% — 10 g per litre — in warm water at about 50 °C. Both are rinsed away with tap water first, then distilled water. Always read the maker's instructions on the bottle: the right concentration matters, and more detergent is not better — extra detergent only means extra rinsing.
Some cleaners must never be used on lab glassware. Household washing-up liquid often contains perfume and colour, which leave residue. Abrasive powders and scouring pads scratch the glass: scratches hold dirt, weaken the glass, and make the next wash harder. Steel wool is worst of all — it leaves tiny metal fibres that rust and contaminate the next experiment.
Detergents also explain why residue matters for living things. A detergent breaks up the cell membrane (the thin skin around a cell), which is why detergent left in a flask can kill cells in a culture. The cell membrane lesson teaches what the membrane is made of and why breaking it kills the cell. If you can still see bubbles when you rinse, keep rinsing — soap left behind ruins the next experiment.
The acid wash: for mineral deposits and metal traces
Detergent cannot remove everything. White scale, metal traces and dried salts need an acid wash: soaking the glassware in dilute acid so the acid dissolves what the detergent could not. For glassware with stubborn stains or residues that detergent cannot shift, an acid solution is the cleaner to reach for.
WHAT: a bath of dilute hydrochloric acid (HCl), usually about 10% v/v (10 parts acid in 100 parts solution). Hydrochloric acid is the acid most often used for the acid wash. HOW: work in a fume hood with goggles and acid-resistant gloves. Immerse the glassware fully in the labelled acid bath and leave it until the deposits dissolve. For stubborn metal contamination, a 6 M HCl soak is used — that step is first-year university work, not school work. WHY: acid dissolves mineral scale (the hard white crust left by hard water and salts) and metal traces. Neither of these comes off with detergent alone.
After the acid bath, rinse three or four times with distilled water. Rinse thoroughly: the rinse must remove all the acid residues from the glass. Do NOT rinse with a base solution to "neutralise" the acid: that leaves salts on the glass, which is a new kind of dirt. Thorough rinsing with water is the correct finish. The acid wash does not remove grease — grease is the base bath's job, as the next section teaches.
Acid also explains a piece of chemistry you meet elsewhere. Acids that oxidise (attack other chemicals by removing electrons) can dissolve metals, which is why an acid wash cleans metal traces at all. The redox lesson teaches oxidation and reduction, and the electrode potentials lesson teaches why some metals dissolve in acid more easily than others.
The base bath: for grease and acid leftovers
The base bath is the partner of the acid wash. Where the acid wash removes minerals and metals, the base bath removes grease and organic residue, and it removes acid leftovers too.
WHAT: a bath of saturated sodium hydroxide (NaOH) or potassium hydroxide (KOH) dissolved in ethanol or methanol — an alcoholic alkali bath. Saturated means as much alkali is dissolved as the alcohol can hold. HOW: work in a fume hood with goggles and gloves. Immerse the glassware fully, soak, then rinse three or four times with distilled water. WHY: a strong base turns grease into soap, a change called saponification (grease plus alkali makes soap). The soap then washes away with water. The base also removes any acid left on the glass.
Three warnings. First, never touch bath liquid with bare hands — a base bath causes deep, slow burns that hurt hours later. Second, a base bath etches glass (slowly eats away its surface), so do not leave glassware in it for days, and never put volumetric glassware in a base bath. Third, as with the acid wash, do NOT rinse with acid to "neutralise" the base: rinse with water. Base baths are first-year university work: school labs use detergent and dilute acid only.
What NOT to do: never neutralise, never mix chemicals
Two mistakes are so common that they need their own section. Both come from the idea that cleaning is faster if you cancel one chemical with another. Both are wrong.
Never neutralise an acid wash with base, and never neutralise a base bath with acid. Rinsing an acid wash with a base solution leaves salts on the glass. Rinsing a base bath with acid does the same. Salts are a new kind of dirt, and they change the concentration of the next solution. The correct finish after any acid wash or base bath is thorough rinsing with water — three or four times with distilled water — and nothing else.
Never mix cleaning chemicals in one bucket. Detergent, acid and base each stay in their own labelled container and are used one at a time. Acid mixed with bleach makes chlorine gas, which is poisonous. Acid mixed with base in a bucket can boil and splash. A bucket with a diluted acid or base solution in it does not make cleaning faster or safer — it makes a new hazard. Use one solution at a time, then rinse, then move on to the next step.
Two cleaners modern labs leave alone. Chromic acid is chromium trioxide dissolved in concentrated sulfuric acid. It was once the standard glass cleaner, but chromium(VI) is a carcinogen (a chemical that can cause cancer), and the used acid is toxic waste that is hard and costly to dispose of. Monash University prohibits chromic-sulfuric acid baths, and Cornell University does not recommend chromic acid at all. The safer substitute is Nochromix, a cleaner mixed with sulfuric acid that contains no chromium and no metal ions. Piranha solution is concentrated sulfuric acid mixed with hydrogen peroxide, usually in a ratio of 3:1 to 7:1. It is violently oxidising (it attacks almost any organic material on contact) and it can explode: the mixture gives off oxygen gas, so it must never be stored in a sealed container. It is used only by trained staff, in a fume hood, with full PPE. Both cleaners are first-year university extension — school labs never use either one. If you ever see an old bottle labelled chromic acid, do not open it — tell your teacher.
Rinsing and the water-break test
Rinsing is not a quick splash at the end. It is the step that decides whether the glass is truly clean, and it has its own test.
Tap water is fine for the first rinses, but it must never be the last rinse. Tap water contains dissolved salts, mainly calcium and magnesium. When tap water dries on glass, the salts stay behind as white spots. Those spots are a new kind of dirt, and they change the concentration of the next solution. That is why the final rinse uses distilled water or deionised water, three or four times, over every surface. Pure water matters for living things too: the osmosis lesson teaches how cells gain or lose water when the solution outside them changes, so even the rinse water can change a biology experiment.
For volumetric glassware there is one extra rinse, called conditioning. After the distilled-water rinse, rinse the burette or pipette with a little of the solution you are about to use, then tip it out. The thin film of solution left inside stops the first drops of your real solution from being diluted by rinse water. Section 11 returns to this.
The water-break test is how you check the rinse worked. Pour distilled water over the inside wall of the glassware and watch it run down. On clean glass, the water stays as one unbroken sheet, a smooth film with no gaps. On greasy glass, the water breaks into beads and droplets, because grease pushes water away. The name says it: if the water film breaks, the glass is not clean. Wash it again from step 2 of the general wash — the detergent soak — not with one quick tap-water rinse, and not by drying it with a towel.
Drying, checking and storing clean glassware
Clean glassware that is dried or stored badly gets dirty again. The finish matters as much as the wash.
Drying: air-dry glassware upside down on pegs or on a drying rack, in a dust-free place. Water drains out, and dust cannot fall in. Air-drying is the recommended method: it avoids contamination from lint. Never dry glassware with a towel: towels leave lint (tiny fibres) and can carry dirt from the last thing they wiped. A drying oven is allowed only for non-volumetric glassware, at 110 °C overnight. Volumetric glassware must never go in an oven — heat changes its volume, and it is calibrated (marked to measure exactly) at 20 °C.
Checking: hold each piece up to the light before you store it. Look for water beads (grease is still there), white spots (salts from tap water), stains, chips and cracks. Chipped or cracked glassware goes straight in the broken-glass bin. It is weak, and it can break under heat or vacuum when you least expect it. Never use a flask with a chipped rim or a cracked base.
Storing: store clean, dry glassware upside down or mouth-down on a shelf, so dust stays out. Do not stack beakers tightly inside each other: they jam, and pulling them apart chips the rims. Flasks stand upright on the shelf once they are fully dry. Cells grown in clean glassware divide normally, as the cell division lesson teaches — and that starts with glassware stored clean.
Broken glass: broken glass goes in the yellow broken-glass bin, never the general waste bin and never the recycling bin. Sweep up pieces with a dustpan and brush, never with bare hands. Pick up tiny splinters with a damp paper towel, then throw the towel in the broken-glass bin too. Tell your teacher about any breakage, so the bench is checked for pieces you missed.
Special cases: volumetric glassware, cuvettes and contaminated glassware
Three kinds of glassware need extra care. The rules here protect both the measurement and the worker.
Volumetric glassware (glassware made to measure an exact volume: volumetric flasks, pipettes and burettes) is calibrated at 20 °C. Never heat it and never dry it in an oven. Clean it by soaking, never by hard scrubbing: scratches inside a burette change its volume. Read the meniscus (the curved top of the liquid surface) at eye level, with the bottom of the curve on the mark. The micrometry lesson teaches how careful measurement works in the lab, and the same care applies here.
Cuvettes (small clear cells that hold a liquid sample while light passes through it for measurement) are used in colorimeters and spectrophotometers, and in microscopy work. Hold a cuvette by its frosted sides only — never touch the clear faces, because fingerprints scatter light and give wrong readings. Never use a brush or an abrasive on a cuvette: soak it in detergent, rinse with distilled water, and air-dry it or blot it with lint-free tissue. Scratches scatter light too, so a scratched cuvette gives a wrong reading. The microscopy lesson teaches how microscopes reveal cells, and clean cuvettes and slides are part of getting a true picture. Dirty glassware also ruins separation work: the chromatography lesson teaches how mixtures are separated, and a dirty column or plate gives a smeared result.
Contaminated glassware (glassware that held microbes, body fluids or hazardous chemicals) is washed only after it is made safe. Glassware that held microbes is soaked in disinfectant first, then washed in the normal way. Glassware used for growing microbes or for culture media must be clean and then sterilised (heated or treated so that no living microbes remain) before use. The culture media lesson teaches how growth media are prepared and why sterile glassware matters. Glassware that held mercury or radioactive material is different: do NOT wash it yourself. Tag it, leave it where it is, and call the lab safety officer or the EHS team (environment, health and safety). Mercury and radioactive waste follow a special disposal route, never the sink and never the broken-glass bin.
Six common mistakes
| Mistake | Why it is wrong | Do this instead |
|---|---|---|
| Drying with a towel | Towels leave lint and dirt on clean glass | Air-dry upside down on pegs or a rack, in a dust-free place |
| Skipping the final distilled-water rinse | Tap water leaves salt spots that change the next solution | Rinse three or four times with distilled water |
| Mixing cleaning chemicals in one bucket | Acid and bleach make poisonous chlorine gas; acid and base can boil and splash | One solution per labelled container, used one at a time |
| Heating soda-lime glass | It cracks from thermal shock at a sudden change of about 40 °C | Heat only glassware you know is borosilicate |
| Putting volumetric glassware in the oven or base bath | Heat changes its volume and base etches the glass, so the calibration is lost | Soak only, rinse, and air-dry |
| Throwing broken glass in the general bin | It cuts cleaners and other workers | Yellow broken-glass bin only, swept up with a dustpan |
One more mistake is worth naming: rinsing an acid wash with base, or a base bath with acid, to "neutralise" it. That leaves salts on the glass. Rinse with water, three or four times, and the job is done.
Worked example: a colorimeter reading that kept going wrong
The problem. A student measures the colour of a solution in a colorimeter (an instrument that shines light through a sample and measures how much light comes out the other side). The readings jump up and down, and the same sample gives a different number every time. The solution is fresh, and the instrument was set to zero with a blank. What went wrong, and how should the cuvette have been handled?
The answer. The student held the cuvette by its clear faces, and fingerprints were left on the glass. Fingerprints scatter light, so less light reached the detector and the reading changed each time the cuvette was turned. The fix, step by step: first, hold the cuvette by its frosted sides only. Second, wash it again — soak it in warm laboratory detergent, never scrub it with a brush. Third, rinse it three or four times with distilled water. Fourth, air-dry it, or blot it gently with lint-free tissue. Fifth, run the water-break test: if the water sheets smoothly, the glass is clean. Then measure again, holding only the frosted sides. The readings now agree, because the light passes through clean, clear glass every time.
Exam-answer pattern (6 marks): "Describe how to clean glassware after a titration." A full answer names six steps in order: (1) pre-rinse with tap water to remove loose residue; (2) soak in warm laboratory detergent and scrub with the right brush; (3) rinse with tap water to remove the soap; (4) use an acid wash if mineral deposits remain; (5) final rinse three or four times with distilled water; (6) dry upside down and check with the water-break test. Each step earns its mark only if you say HOW it is done and WHY it matters.
Frequently asked questions
Can I use household washing-up liquid? Not for analytical work. It often contains perfume and colour, which leave residue. Use a laboratory detergent such as Decon 90 or Alconox, at the maker's concentration.
Why distilled water for the final rinse? Tap water leaves dissolved salts as white spots when it dries. Distilled water leaves nothing behind.
How do I know the glassware is clean? Run the water-break test: pour distilled water over the inside wall. An unbroken sheet means clean glass. Beads and droplets mean grease is still there — wash again from the detergent soak.
Can I put a measuring cylinder in the oven? No. A measuring cylinder is volumetric glassware, calibrated at 20 °C. Heat changes its volume. Air-dry it upside down.
What do I do with a chipped flask? Put it in the broken-glass bin and tell your teacher. Never use chipped or cracked glassware: it is weak and can break under heat or vacuum.
What does PPE stand for? Personal Protective Equipment — the goggles, gloves, lab coat and closed shoes that protect you in the lab. For acids and bases, the gloves must be acid-resistant.
Sources
School syllabuses: AQA GCSE Biology 8461 — 10 required practicals, practical skills AT 1, AT 2, AT 8. OCR GCSE Biology B J247 — Topic B7 Practical skills, 8 PAGs (Practical Activity Groups). Edexcel GCSE Biology 1BI0 — 8 core practicals. AQA A-level Biology 7402 — sections 7.1 to 7.4, 12 required practicals, CPAC endorsement (Common Practical Assessment Criteria), Required Practical 6 on aseptic technique (working without letting microbes in). OCR A-level Biology A H432 — Module 1 Practical skills (1.1, 1.2), 12 PAGs. Edexcel A-level Biology A (Salters-Nuffield) 9BN0 and Biology B 9BI0 — core practicals, CPAC endorsement. AP Biology Course and Exam Description — 6 science practices, at least 25% of time on laboratory work, 13 investigations. IB Biology Guide (2023) — internal assessment 10 hours, 20% of the grade, 24 marks, 4 criteria; enzymes C1.1, respiration C1.2.
Cleaning methods and numbers: University of Nebraska-Lincoln standard procedure — 10% v/v HCl acid wash. University of Rochester glassware guide — 6 M HCl for stubborn metal contamination, saturated NaOH/KOH base bath. Decon Laboratories Decon 90 data sheet — 2–5% solution, soak 2–24 hours, 40–50 °C. Alconox Inc. directions — 1% solution (10 g per litre), warm water about 50 °C. Monash University — chromic-sulfuric acid baths prohibited. Cornell University — chromic acid not recommended. Michigan State University EHS — mouth pipetting prohibited. Full detail, with an honesty note on anything that could not be checked against the original spec documents, is in syllabus-research.md in the #97 package.
Honesty note: no school syllabus names glassware cleaning as a topic of its own. It is a practical skill that underpins the required practicals: without clean glassware, no required practical gives a true result. Acid baths, base baths, chromic acid, piranha solution and cuvette care are first-year university and laboratory enrichment, marked as such in this lesson.
Continue learning
- Glassware cleaning in the laboratory — the full lesson - the full lesson on glassware cleaning, with every step explained in depth.
- Lab Safety Quiz: Rules, PPE, Chemicals, Spills and Fire - test the safety rules this lesson uses.
- Microscopy and Cell Size: How Microscopes Reveal Cells - clean slides and cuvettes make a true picture.
- Cell Division: Mitosis, Meiosis and the Cell Cycle - cells grown in clean glassware divide normally.
- Preparation and pH Adjustment of Culture Media: Complete Guide - sterile glassware for growing microbes.
- Exploring the World of Chromatography: Principles, Applications, and Types - dirty glassware smears a separation.
- Redox Reactions in Biological Systems: Oxidative Stress, Antioxidants and Redox Balance - the oxidation chemistry behind the acid wash.
- Electrode Potentials and Redox Reactions: Cells, Batteries and Corrosion - why some metals dissolve in acid more easily than others.
20 Explained MCQs — answers hidden until opened
Open each question to reveal its answer and explanation. The interactive quiz below uses a different set of questions.
1. Why is glassware pre-rinsed before the main wash?
A. To remove grease baked onto the glass B. To dry the glassware ready for use C. To kill microbes on the glass D. To wash away loose particles and old solution before scrubbing
Answer: D. The pre-rinse washes away loose particles and old solution while they are still wet and easy to shift. Once they dry on, they are far harder to remove. Grease is the detergent wash's job, not the pre-rinse's.
2. Which water is used for the final rinse of glassware?
A. Distilled water B. Mineral water C. Tap water D. Sea water
Answer: A. Distilled water is used for the final rinse because it leaves nothing behind when it dries. Tap water leaves salt spots, and mineral water and sea water are full of dissolved salts.
3. Why is a greasy flask soaked in a base bath?
A. The base turns grease into soap and clears acid leftovers B. The base dissolves mineral scale and metal traces C. The base kills microbes on the glass D. The base makes the glass shine
Answer: A. A strong base turns grease into soap, which washes away with water, and it also clears acid leftovers. Mineral scale and metal traces are the acid wash's job, not the base bath's.
4. A flask has just come out of the acid bath. What comes next?
A. Dry it at once with a towel B. Rinse it well with distilled water C. Rinse it with a base solution D. Put it straight back on the shelf
Answer: B. After an acid wash the glass must be rinsed well with distilled water, three or four times. Rinsing with a base solution is wrong advice: the base reacts with the acid and leaves salts on the glass, a new kind of dirt.
5. What safety gear is essential when working with acids and bases in glassware cleaning?
A. Bare hands and ordinary glasses B. A face mask only C. Safety goggles and acid-resistant gloves D. No safety gear is needed for dilute solutions
Answer: C. Acids and bases can splash and burn skin and eyes, so safety goggles and acid-resistant gloves are essential. Ordinary glasses do not protect the eyes from splashes, and bare hands are never safe around acids and bases.
6. What job does the detergent wash do in the general wash?
A. It lifts grease off the glass B. It dissolves mineral scale on the glass C. It dries the glassware D. It removes loose particles from the glass
Answer: A. The detergent wash lifts grease off the glass: the surfactant in the detergent grabs the grease and pulls it into the water. Loose particles are removed by the pre-rinse, not by the detergent wash.
7. Which brush reaches the bottom of a burette without forcing?
A. A toothbrush B. A short wide brush C. A long thin brush D. A wire brush
Answer: C. A burette is a long narrow tube, so only a long thin brush reaches the bottom. The brush must never be forced - if it does not fit, soak the glassware longer instead of pushing harder.
8. How should clean glassware be dried?
A. Dry it with a hairdryer on full heat B. Towel-dry it with any cloth at hand C. Leave it wet on the bench D. Air-dry it upside down in a dust-free place
Answer: D. Clean glassware is air-dried upside down in a dust-free place, so water drains out and dust cannot fall in. Towel-drying leaves lint on the glass, and a hairdryer blows dust onto it.
9. A student pours acid and bleach into the same cleaning bucket. What is the danger?
A. They react and make chlorine gas, which harms the lungs B. They make the bucket change colour C. They make the water boil gently and safely D. They cancel each other out and clean better
Answer: A. Acid and bleach must never be mixed: they react and make chlorine gas, which harms the lungs. Cleaning chemicals always stay in separate baths - never mix them in one bucket.
10. What should be used on glassware with stubborn stains that detergent cannot shift?
A. A dry cloth B. A 10% v/v hydrochloric acid wash C. Plain tap water only D. A stronger dose of detergent
Answer: B. Stubborn stains and mineral deposits need a 10% v/v hydrochloric acid wash, which dissolves mineral scale and metal traces. Detergent cannot remove mineral scale, and plain water cannot shift a stubborn stain.
11. Which water is commonly used to pre-soak heavily soiled glassware?
A. Tap water B. Mineral water C. Distilled water D. Boiling oil
Answer: A. Tap water is commonly used for pre-soaking heavily soiled glassware, to loosen dried-on dirt before the main wash. Distilled water is saved for the final rinse, where purity matters.
12. What does PPE stand for?
A. Professional Productive Equipment B. Personal and Professional Equipment C. Personal Protective Equipment D. Protective and Productive Equipment
Answer: C. PPE stands for Personal Protective Equipment - the goggles, gloves, lab coat and other gear that protect the worker's body from chemicals, splashes and cuts.
13. After an acid wash, should you rinse the glass with a base solution to neutralise the acid?
A. No - a base rinse leaves salts behind; rinse well with distilled water B. Yes - but only if the base is very strong C. No - skip rinsing and dry the glass at once D. Yes - a base rinse is the correct way to neutralise the acid
Answer: A. Rinsing an acid wash with a base solution leaves salts on the glass, a new kind of dirt. The correct finish is thorough rinsing with distilled water, three or four times - never neutralise with base.
14. At what point in the cleaning job must acid-resistant gloves be on your hands?
A. Only when handling bases, never acids B. Always, whenever acids or bases are handled C. Only when handling acids, never bases D. Never - gloves make handling glassware harder
Answer: B. Acid-resistant gloves are worn always, whenever acids or bases are handled. Both acids and bases can burn the skin, so the gloves stay on for the whole job, not just for one of them.
15. Why is air-drying better than drying glassware with towels?
A. Towels cost too much money B. Towels dry the glass too fast C. Towels make the glass crack D. Towels leave lint on the glass
Answer: D. Towels leave lint - tiny fibres - on the glass, and lint is contamination that spoils the next experiment. Air-drying in a dust-free place leaves nothing behind.
16. Which acid is commonly used in the acid wash for glassware?
A. Hydrochloric acid B. Acetic acid C. Nitric acid D. Citric acid
Answer: A. Hydrochloric acid is the acid commonly used in the acid wash, as a 10% v/v solution, to dissolve mineral scale and metal traces that detergent cannot remove.
17. Why must glassware be rinsed thoroughly after an acid wash?
A. To speed up drying B. To make the glass shine C. To stop the glass from scratching D. To remove acid residues
Answer: D. Thorough rinsing removes acid residues from the glass. Leftover acid would react with the next solution and spoil the experiment, so the rinse is done three or four times with distilled water.
18. A beaker has alkaline residues left on it. Which wash clears them?
A. A rinse with distilled water only B. A detergent wash only C. A base bath, because more alkali clears alkali D. An acid wash, because acid dissolves alkaline residues
Answer: D. An acid wash clears alkaline residues, because acid dissolves them. A base bath would be wrong here: it adds more alkali to glass that already has alkaline residues on it.
19. How should clean glassware be stored to keep it clean?
A. Covered with a cloth that sheds lint B. Upside down, so dust cannot fall in C. Right way up with the mouth open D. Stacked wet on top of each other
Answer: B. Clean glassware is stored upside down, so dust cannot fall in and any last drops of water drain out. Stacking wet glassware traps water and dirt, and a cloth cover sheds lint.
20. What is the safe rule for the cleaning bucket?
A. Use one bucket for all chemicals to save time B. Add every cleaning solution to one bucket in the right proportions C. Keep each cleaning chemical in its own bath; never mix them in one bucket D. Mix acid and base in one bucket so they neutralise each other
Answer: C. Cleaning chemicals must never be mixed in one bucket. Acid and bleach make chlorine gas, and acid and base can boil and splash. Each chemical stays in its own bath, and the bucket holds one solution at a time.
Separate Interactive Quiz — 20 different questions
These quiz questions are different from the MCQs above. Select an answer for each question. You will not see whether an answer is correct until you submit all 20 questions. Use Reset to try again.
0 Comments
Have a biology question or spotted an error?
Send feedback to PreachBio →